MODEL
FRDD
Slow response, fixed orifice, bypass/restrictive, priority, flow control valve
SERIES 2 / CAPACITY: 45 L/min. / CAVITY: T-2A
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow
at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow
may be used in a secondary circuit.
TECHNICAL DATA
Cavity T-2A
Series 2
Capacity 45 L/min.
Maximum Operating Pressure 350 bar
Maximum Input Flow 120 L/min.
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990202007
Seal kit - Cartridge Polyurethane: 990002002
Seal kit - Cartridge Viton: 990202006
Model Weight 0.20 kg.
(X)CONTROL
X Not Adjustable
C Tamper Resistant - Factory Set
K Handknob
L Tuning Adjustment
O Handknob with Panel Mount
(A)SETTING RANGE
A Replaceable Orifice .1 - 12 gpm (0,4 -
45 L/min.)
B Permanent Orifice .1 - 12 gpm (0,4 - 45
L/min.)
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/FRDD
For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
NOTES
Model Code Example: FRDDXANCONFIGURATION OPTIONS